computer or control room by securely viewing DeltaV data and alarms on mobile devices.??
DeltaV users can now have the plant at their fingertips whenever they need it and maintain situational awareness of their process at all times." DeltaV Mobile is an intuitive mobile app that provides read-only access of DeltaV data and alarms from multiple DeltaV systems. Users can access this data from mobile devices on site with Wi-Fi or offsite with secure VPN. DeltaV Mobile provides the same richness of data and alarms from DeltaV operator stations on built-for-purpose mobile screens. Users can receive notifications on DeltaV alarms. DeltaV Operations, Process Control, PlantWeb All / Cross-Industry Engineer Workshop Mariana Dionisio Emerson Automation Solutions - - - - - - - - Emerson Product Update - - -
6. Emerson Presents Approved Critical Electrical Assets Everywhere Where to Start Monitoring Most companies have many electrical critical assets currently not monitored for situations causing unexpected failure. Furthermore, most plants only inspect these assets periodically. As companies move forward toward continuous monitoring and pervasive sensing of their electrical assets, it can be mind-numbing to decide where to start. Which electrical asset should be monitored first? This paper will discuss the importance of moving from periodic maintenance to continuous monitoring. It will answer the question of why it’s important to monitor the condition of electrical critical assets, the types of monitoring that can be implemented to get a holistic view of the asset, which electrical asset is a good candidate for monitoring, and how to get started The problem or challenge this paper address is the importance of moving from periodic to continuous monitoring 24/7, How an end user can determine which Electrical assets are good candidates for pervasive sensing, which ones should be monitored, types of monitoring solutions and what a typical application looks like. The benefit is a holistic view of the asset giving an early warning of potential issues that can cause an unscheduled outage costing companies hundreds of thousands to millions of dollars. This 24/7 monitoring of critical electrical assets is a way to Increase electrical critical asset performance and reliability, lower maintenance costs, and avoid catastrophic failures. Adding Temperature, Partial Discharge and Humidity sensors to Critical Electrical assets. Monitoring these assets 24/7 in a control system. Moving from Periodic monitoring or operator rounds to Pervasive Sensing or Real time monitoring. Wireless Efficiency, Wireless, Safety, Reliability, Predictive Technology All / Cross-Industry Consultant, Vice President, Supervisor / Manager / Dept. Head, Project Manager / Lead, President / Principal, Plant or General Manager, Engineer Workshop Mark Sagstetter Rosemount - - - - - - - - Emerson Service Update - - -
6. Emerson Presents Approved The new normal for Process Radar – The new two-wire FMCW radar’s are here! What are the main differences between FMCW and pulse radar and what makes the FMCW radar the best fit for most application conditions? Does the technology really matter? How is the level measurement affected by the sensitivity of the radar? In a simple wording, we will explain this by looking at the theory behind new FMCW radars. Radar is the fastest growing level measurement technology for a reason and you will see when and how radar increases plant efficiency and improves your safety on common applications. We will also cover the latest news regarding FMCW radar′s. Previously radars used to be perceived as maintenance free but “complicated” to use and “not sufficient” for the most demanding applications. We will explain the difference between pulse and FMCW radars and how they will act during different conditions. We will explain how the latest two-wire FMCW radar′s really increase efficiency while providing reliable, safe, and low maintenance solutions. New FMCW radar’s are 30 times more powerful and provide 3 times better resolution - by understanding how to leach the power, one can address even demanding level measurement challenges. The ultimate goal - the safest, reliable and cost-efficient level solution is now within reach! There are several types of non-contacting radars and this workshop will explain the differences between common technologies such as FMCW and pulse radar and how microwave frequencies, tank environments, process conditions and media characteristics will impact your radar's performance. We will also cover how users contribute to make new radar generations easy to use. Instrumentation - Level Installation Best Practices, Process Control, Predictive Technology All / Cross-Industry Consultant, Technician / Analyst / Specialist, Supervisor / Manager / Dept. Head, Sales / Marketing, Project Manager / Lead, Plant or General Manager, Operator, Engineer Workshop Ingemar Serneby Emerson Process Management Andreas Hessel Emerson Process Management - - - - - - Emerson Product Update - - -
6. Emerson Presents Approved Reaping benefits in the bulk solids industry with multiple points measurement using 5708 3D Scanner Measuring the volume of bulk solids is never easy because surfaces are uneven and irregular. This makes it difficult to get reliable accuracy in volume measurements with current technologies. Having a multiple point measurement system allows for easy implementation while gaining better accuracy and repeatability in volume measurements of bulk solids. The benefits provided by the system also keeps workers safety on the ground. For bulk solids, a single point measurement on a wide, uneven surface does not give adequate representation for accurate volume measurements. Solid material tend to stick on the vessel sides and cannot be detected using a single point device.? Dusty environment in solid application obstructing reliable measurement.? Some materials could not be measured using existing technologies. "? Highly accurate volume reading of bulk solid material can allow for reduction in safety stocks, optimization of purchasing decision and to eventually save money.
? Unaffected by dusty application. Independent of vessel or warehouse size ( storage silo, domes, open bins and warehouses)
? An automated system keeps workers safety on the ground
? Real time data availability for all users" The Rosemount 5708 3D Solids Scanner delivers accurate volumetric measurement of bulk solids. The scanners can work together to map out the surface of material inside the vessel and the software uses all the points collected to calculate the volume of the material. All of the measurements are automated to keep workers on the ground. Instrumentation - Level DeltaV, Process Control, Ovation All / Cross-Industry, Refining, Pulp & Paper, Power & Utilities, Pharmaceutical & Life Sciences, Petrochemicals, Oil & Gas Midstream (Pipelines, Terminals), Metals, Mining, Cement & Glass, Food, Beverage & Consumer Goods, Engineering (OEM's, E&C's, Integrators), Chemicals (Industrial, Specialty) Engineer, Technician / Analyst / Specialist, Supervisor / Manager / Dept. Head, Sales / Marketing, Project Manager / Lead, Plant or General Manager, Operator Workshop Asael Sharabi Emerson Process Management Eran Perlstein Emerson - - - - - - Emerson Product Update - - -
6. Emerson Presents Approved DeltaV Virtualization – Product Update This workshop provides a product overview with details of recent product enhancements for DeltaV virtualization hardware and software.? DeltaV Virtual Studio is an integrated software application for virtual DeltaV system development, testing, operator training, and on-line production.? A virtual platform offers benefits of less hardware, increased productivity and flexibility, higher availability, and disaster recovery. Virtualization is becoming standard practice in many industries as a means to improved productivity, reduced costs, and higher system availability.? But virtualization can be complex and unfamiliar to control system personnel.? How can manufactures capture the virtualization benefits without creating an overly complex solution which is hard to implement and maintain? DeltaV Virtualization provides reduced lifecycle costs, increased project flexibility, enhanced simulation and training, and higher system availability.? DeltaV Virtual Studio with an integrated hardware platform reduces complexity and increases ease of implementation and maintenance. Designed specifically for automation engineers, DeltaV Virtual Studio reduces complexity while delivering all the benefits of virtualization technology.? DeltaV’s integrated hardware platform is designed specifically for virtualization using a Dell PowerEdge VRTX consisting of blade servers, network storage, and shared switches, preconfigured and tested for use with DeltaV Virtual Studio. Virtualization DeltaV, Virtualization, Information Technology All / Cross-Industry Engineer Workshop John Caldwell Emerson - - - - - - - - Emerson Product Update - - -
6. Emerson Presents Approved Have a challenging pressure application?? Consider it solved with the Rosemount 3051 New pressure measurement requirements are becoming more and more challenging with unique and stringent conditions.? To answer those challenging applications, Emerson continues to innovate pressure technology with the Rosemount 3051 Pressure Transmitter to meet the requirements and provide users with a robust and reliable pressure measurement.? These applications range from the coldest ambient temperatures to the highest pressures and even unique material compatibility concerns.? The 3051 can now measure pressure up to 20,000 psi and also at ambient temperatures as low as -60C all while maintaining high accuracy with SIL certification.? The 3051 also improves the measurement success of applications at risk of hydrogen permeation at high pressures. Three major challenges have emerged:? First, users in cold climates have required a transmitter to operate down to -60C ambient temperatures.? Second, hydrogen fueling stations have emerged and required a transmitter that can withstand hydrogen permeation at high pressures.? Last, high pressure applications for wellhead pressure and chemical injection are requiring a high performance transmitter. Users are able to measure accurately in outdoor applications and eliminated heated enclosures is all applications, including SIS.? Hydrogen filling stations and other applications at risk of hydrogen permeation can measure higher pressures with easier to install in-line pressure transmitters. High pressure applications can easily measure with high accuracy, full featured pressure transmitters. The Rosemount 3051 is now available with new options. Cold Temperature options extend the rated ambient temperature to -60C at high measurement accuracy with SIL certification.? A new high pressure range now expands measurement capability to 20,000 psi.? Cataloged gold plated SST isolating diaphragms on in-line pressure transmitters allow protection against hydrogen permeation up to 20,000 psi. Instrumentation - Pressure Installation Best Practices, SIS / SIL, Instrumentation - Pressure All / Cross-Industry Consultant, Technician / Analyst / Specialist, Supervisor / Manager / Dept. Head, Project Manager / Lead, Operator, Engineer, Director Workshop Emily Saopraseuth Emerson Pamela Kunkel Emerson - - - - - - Emerson Product Update - - -
6. Emerson Presents Approved DeltaV Product Update: Recent Licensing Changes and Enhancements Historically, licensing of the DeltaV DCS has been an often misunderstood and, in some cases, complex topic. This workshop will explain several beneficial enhancements and simplifications made to the DeltaV system licensing model recently. Explanations and clarifications for several new license options will be provided. The workshop will also give users the opportunity to provide licensing feedback and suggestions for future enhancement. Historically, DeltaV systems utilizing several signals (values) from intelligent field devices (Ff, HART, PROFIBUS DP, DeviceNet, etc.) within the control strategy required an appropriate Device Signal Tag (DST) license (i.e. cost) for each signal referenced in the control configuration. With recent licensing changes, customers are not penalized for utilizing the field device intelligence. With only a single DST license required for a field device, customers are now able to utilize valuable parameters from their devices in control strategies and operator/maintenance displays, resulting in operational benefits by allowing abnormal situation prevention and better cause/effect troubleshooting. The newly implemented I/O signal DST counting rules in the DeltaV system require only a single DST license for each intelligent field device, no matter how many signals are referenced from the device. Batch and Advanced Unit Management licensing was moved from a DST basis to a “unit” basis. Temporary engineering seat licenses and view only operator station licenses were introduced. DeltaV Business, Engineering, DeltaV All / Cross-Industry Engineer, Sales / Marketing, Project Manager / Lead Workshop Randy Balentine Emerson Automation Solutions - - - - - - - - Emerson Product Update - - -
6. Emerson Presents Approved DeltaV Batch Product Update This product update session will provide a first-hand look at the DeltaV Batch enhancements that are coming in the DeltaV v14 release. In addition, we will explore how you can leverage the new DeltaV Discovery, PK Controller and DeltaV Mobile offerings to improve the overall efficiency of your product development lifecycle from research, through engineering design, to production. Product lifecycle management Improve overall product development efficiency and reduce time to market. Leverage the integrated Batch capabilities in DeltaV Discovery, PK Controller and DeltaV Mobile to deliver a complete solution that can easily migrate from the research and development environment, through engineering design, to the final production phase of the product development lifecycle. DeltaV Operations, Syncade, Process Control Chemicals (Industrial, Specialty), Refining, Pulp & Paper, Pharmaceutical & Life Sciences, Petrochemicals, Food, Beverage & Consumer Goods, Engineering (OEM's, E&C's, Integrators) Consultant, Technician / Analyst / Specialist, Supervisor / Manager / Dept. Head, Project Manager / Lead, Plant or General Manager, Operator, Engineer Workshop Kam Yuen Emerson - - - - - - - - Emerson Product Update - - -
|