觸點(diǎn)類型
|
2路常開安全觸點(diǎn)輸出
|
|
|
1路反饋回路
|
|
觸點(diǎn)材料
|
AgCuNi,+ 0.2 ?m Au
|
|
切換電壓
|
250 V AC/DC (常開觸點(diǎn)、常閉觸點(diǎn),注意負(fù)荷曲線)
|
|
最小切換電壓
|
15 V AC/DC (常開觸點(diǎn)/常閉觸點(diǎn))
|
|
限制連續(xù)電流
|
5 A (N/O觸點(diǎn),請(qǐng)注意衰減)
|
|
|
100 mA (常閉觸點(diǎn))
|
|
啟動(dòng)電流
|
5 A (N/O觸點(diǎn))
|
|
|
100 mA (常閉觸點(diǎn))
|
|
最小沖擊電流
|
5 mA (常開觸點(diǎn)/常閉觸點(diǎn))
|
|
總電流值的平方
|
50 A2 (注意降低值)
|
|
額定功率值(電阻負(fù)載)
|
120 W (24V DC,τ=0ms,常閉觸點(diǎn): 2.4W)
|
|
|
192 W (48V DC,τ=0ms,常閉觸點(diǎn): 4.8W)
|
|
|
162 W (60VDC,τ = 0ms,常閉觸點(diǎn): 6W)
|
|
|
66 W (110V DC,τ=0ms,常閉觸點(diǎn): 11W)
|
|
|
60 W (220V DC,τ=0ms,常閉觸點(diǎn): 22W)
|
|
|
1250 VA (250 V AC,τ=0ms,常閉觸點(diǎn): 25VA)
|
|
額定功率值(電感負(fù)載)
|
72 W (24V DC,τ=40ms,常閉觸點(diǎn): 2.4W)
|
|
|
43 W (48V DC,τ=40ms,常閉觸點(diǎn): 4.8W)
|
|
|
41 W (60VDC,τ = 40ms,常閉觸點(diǎn): 6W)
|
|
|
35 W (110V DC,τ=40ms,常閉觸點(diǎn): 11W)
|
|
|
48 W (220V DC,τ=40ms,常閉觸點(diǎn): 22W)
|
|
通斷容量
|
最小 75 mW
|
|
機(jī)械壽命
|
10x 106開關(guān)次數(shù)
|
|
輸出熔斷器
|
10 A gL/gG (N/O觸點(diǎn))
|
|
|
4 A gL/gG (適用于低需求應(yīng)用場(chǎng)合)
|
|
|
150 mA 快速熔斷 (常閉觸點(diǎn))
|